Narrow Gage OSL All-Bolted Clip Angles

Narrow Gage OSL all-bolted clip angle settings for angle size, gage on leg dimensions, staggered pattern, standard piecemarks, and more.

To specify this type of standard clip angle in the model :

.
  • Narrow Gage OSL All-Bolted Clip Angles are double clip angles that shop bolt to the supported or supporting member and are designed as the supported beam's end connection when 'Narrow Gage', 'Bolted' (to supported), 'Bolted' (to supporting), 'Both' (sides of web) and shop attach to 'Supported' (or 'Supporting') are set in " Connection specifications " for auto standard , user defined or beam-window-specified clip angles.
  • For a joist, the required settings that result in a clip angle being designed using this clip angle configuration are 'Narrow Gage', 'Bolted' (to supported), 'Bolted' (to supporting), and 'Both' (sides of web).
  • Clip angles can also be used for the attachment of vertical brace and horizontal brace gusset plates in various framing situations. For vertical brace to beam & column framing situations, connection design attaches the vertical brace gusset plate to the column using the same clip angle configuration that is used to attach the beam to the column. A "Combine beam/vbrc clip angles" option in the beam's Connection specifications lets you specify whether or not those clip angles are combined.

or

Each bolt diameter is a distinct clip angle configuration that needs to be set up separately. The list box shows imperial sizes when the " Available bolt diameters " is 'Imperial '. Metric sizes are shown when the " Available bolt diameters " is 'Metric '. If "Available bolt diameters" is set to 'Both ', the primary dimensioning " Units " determine whether the list box shows imperial or metric bolt sizes.

Standard angle size: The angle section size for the specific bolt diameter that has been selected. The angle must be listed in the local shape file.

To enter an angle section size: Either type in the section size that you want (e.g., ' L4x3 1/2x5/16 '), or press the "file cabinet" browse button ( ) and choose an angle section from the list of angles in the local shape file .

Attach long leg to: Supported or Supporting . This applies when a " Standard angle size " with unequal legs has been entered.

' Supported ' bolts the long leg of the angle to the supported beam or the knife plate of the joist.

' Supporting ' bolts the long leg of the angle to the supporting beam or column.

Hole type in leg to supported member: Standard round or Short slot or Long slot or Oversized or User slot #1 or User slot #2 .

Gage on leg to supported member: The distance from the outside corner of the clip angle to the center of the column of holes on the leg that bolts to the supported beam or the knife plate of the joist.

Hole type in leg to supporting member: Standard round or Short slot or Long slot or Oversized or User slot #1 or User slot #2 .

Use gage on leg to supporting member for: Slots only or All hole types .

' Slots only ' instructs connection design to apply the " Gage on leg to supporting member " only when the " Hole type in leg to supporting member " is ' Short slot ' or ' Long slot ' or ' User slot #1 ' or ' User slot #2 '. On standard round holes, connection design sets the gage based on the " Narrow gage " center-to-center hole distance and the web thickness of the supported beam.

' All hole types ' instructs connection design to apply the " Gage on leg to supporting member " for all hole types, including standard round holes.

Gage on leg to supporting member: The distance from the outside corner of the clip angle to the center of the column of slots on the outstanding leg (on the leg that bolts to the supporting beam or column).

For slots, connection design may apply a different GOL than that which is entered here in order to permit the bolts to fit in the slots at the "Narrow gage" center-to-center hole distance.

Begin staggered bolt pattern at bolt diameter: The minimum bolt diameter ( inches or mm ) at which bolt patterns should be staggered.

To make an entry: You can type in a diameter, or select a bolt diameter from the menu ( ). Diameters listed on the menu come from Home > Project Settings > Job > Bolts, Washers, and Holes > Bolt Settings > the " Available bolts " list.

Clip Angle Piecemarks

When connection design creates a clip angle that exactly matches a clip angle defined on that table, SDS2 piecemarking assigns the piecemark that is entered for that clip angle. Both the GOL and the number of rows must match exactly.

Note : To edit the Clip Angle Piecemarks table, your current Fabricator must be the Master Fabricator. This ensures that standard piecemarks for clip angles come from a single setup source, regardless of your current Fabricator.

For clip angles in this configuration: The GOL is set according to the " Narrow gage " center-to-center hole distance plus the web thickness of the supported beam (or the joist's knife plate thickness). If a standard piecemark from this table matches the GOL and number of rows of bolts in the actual designed clip angle, that piecemark is assigned.

Column heads (GOLs): Each column head on this table is a GOL (gage on outstanding leg). These GOLs are calculated from the "Narrow gage" center-to-center hole distance that is entered in Clip Angle Settings .

Rows: Each row on the Clip Angle Piecemarks table is a number of rows of bolts.

To make entries: click the cell that corresponds to the GOL (gage on outstanding leg) and number of rows of bolts desired. Type in a clip angle standard piecemark of up to 61 characters.

  • The position of these form buttons on the screen tells you what settings they apply to. Click here for more information.
  • You can Copy ( ) the settings on this screen , then Paste ( ) those settings to a different screen of the same type.
  • Save ( ) saves a file to a global folder ( ) that is used by your current version of SDS2. Give the file a name that will help other users identify its purpose. Load ( ) replaces the settings on this screen with the settings that are stored in the file that you select.
  • When editing multiple screens at the same time, Paste and Load replace mixed entries to a single field with a single entry. Copy and Save ignore fields with mixed entries, treating them as if they have no entry or do not exist.

OK (or the Enter key) closes this screen and applies the settings.

Cancel (or the Esc key) closes this screen without saving any changes.

Reset undoes all changes made to this screen since you first opened it. The screen remains open.

  • Settings applied here are for your current Fabricator . Each Fabricator in your current Job is a different collection of settings.
  • To edit the Clip Angle Piecemarks table on this screen, your current Fabricator must be the Master Fabricator, otherwise this table is disabled .
  • If your current Fabricator is not the Master Fabricator, the piecemarking routine will continue to reference the version of the Clip Angle Piecemarks table in the Master Fabricator.
  • If the Clip Angle Piecemarks table on this screen is filled out, any standard piecemark from the table can be added as an existing material .
  • Red or yellow exclamation point icons ( or ) indicate that a setting field is required to be filled out or corrected before the settings can be accepted by clicking OK. Hover your mouse cursor over the icon to make a tooltip appear with more information.